Get your eco-friendlysolution against scale and rust today.The Kashyap-Impulse-Technology Treats the water with electronic in pulses and does not use any chemicals or salt.The scale is washed away with the water as a fine powder.
Anti-scale system contains programmed micro-processor to controls the unit to create electronic impulses inside the pipe by the bands wrap on the pipe. These bands create impulses inside the pipe which changes the shape of calcium crystals in the water.
Anti-Scale System works on all pipe materials iron,copper,steel, plastic,PVC,PE-X,
Easy Do-it-Yourself installation without cutting the pipes
Anti-Scale System works with special conductive impulses and does not use magnetism
Maintenance-Free
Benefits of anti-scale system
The electronic anti-scale system is the salt-free alternative to water softeners
Secure reduction of scale deposit in the whole piping system.
Less time and effort spent on repairs and maintenance in your home, hotel or factory
Filters,shower nozzles and shower heads stay clean
Faster cleaning of kitchen and bathroom
Considerable savings in washing and cleaning agents
Important minterals remain in the water for a healthy diet.
Food and beverages keep their natural taste
Skin feels less dry and softer
Increase in productivity
Feature
No Maintenance, No Plumbing & Easy to Install
Main pressure unaffected
Little space required and safe.
Low running cost,negligible power consumption.
Effective on PVC,HDPE,Copper or Steel Pipe.
No waste water.
The Anti-scale system effects
1. Anti-scale system stops scaling on surfaces
Anti-scale system modifies the crystallization of the calcium. The scale loses its adhesive power and is washed away with the water as a fine powder.
Anti-scale system contains programmed micro-processor to controls the unit to create electronic impulses inside the pipe by the bands wrap on the pipe. These bands create impulses inside the pipe which changes the shape of calcium crystals in the water.
2. Anti-scale system stops scaling on surfaces
Anti-Scale System carefully dissolves existing incrustations in the piping system.Only a thin protective layer remains in the pipe.
3. Anti-scale system
Anti-Scale System generated a controlled electrophoresis process. which produce a protective metal carbonate layer. It acts as protection againt rust and corrosion.
Get your solution against scale and rust today
The Anti-scale system:
How does it work?
Anti-scale system is physical water treatment. It is completely salt and chemical free treatment. Unlike Ion exchange treatment by changing the chemical properties of the water, Anti-scale system changes the physical characteristics of scale crystals so they lose their property to get deposited. Anti-scale system directly fits on the pipe from outside and no need to cut the pipe.
Anti-scale system contains programmed micro-processor to controls the unit to create electronic impulses inside the pipe by the bands wrap on the pipe. These bands create impulses inside the pipe which changes the shape of calcium crystals in the water.
Problems caused by scaling
Scale deposits inside the pipes and create many problems:
- Blocking of piping systems
- Deposits on the surfaces
- Increase in heating cost
- Removing scale requires expensive cleaning
- Rusting and corrosion inside the pipes
1. Anti-scale system for hard water problems
Anti-scale system prevents scaling insides the piping system and equipment
Water starts scale particles deposits inside the water when untreated and they get deposited and becomes solid. By treating water with Anti-scaling system, the impulse changes the shape of calcium and magnesium particles giving the physical treatment. Particles become small powder inside the water and are unable to attach to each other. The scale becomes a fine powder and washes away. Also it prevented from forming the new scale.
Anti-scale system creates fine powdered particles
With the impulse treatment particles change their shape and become fine powdered. They grow stronger as they travel longer inside the piping system. These particles together become larger particles and take more time to get separated before they lose their effect. These particles grow faster in warm water and its effect stays longer in warm water.
2. Anti-scale system cleans the piping system
Hard scale deposit faster when it is not treated:
a. Calcium particles sticks to each other and scale deposits develop inside the pipes faster. These deposits produce carbonic acid (H2CO3).
b. Simultaneously, carbonic acid breaks down existing scale deposits. This is the natural way of resolving the process. But as the build-up process occurs faster than the natural resolving process, and scale start deposited inside the pipe thus reduces the diameter of pipe.
With anti-scaling system this process is reverse and the scale deposit process get slower and scale build-up doesn�t take palce. Thus, the scale removing is much faster than the build-up process, and it also removes the existing deposits more effectively. The carbonic acid generated during the process dissolves the scale. Thus, the scale deposits are removed from the pipe.
Rust removal through scale
Iron particles are deposited along with the scale deposits inside the pipe. Therefore, scale and rust mix together and form red deposits inside of the pipes. When the anti-scaling system, the scale get dissolves and rust is also removed along with it. This process of removing the scale deposits is moderate: scale dissolves into the water and washes away. As these are natural minerals, water remains safe to drink.
3. Anti-scaling system against rust damage and perforation
Iron and copper oxidation occurs in all metal pipes when it comes in contact with hard water. These oxides have a serious negative effect on pipe surfaces and can even cause corrosion.
Anti-scaling system with the impulse on the pipe develops an electrophoresis effect and makes a protected metal-carbonate covering on the pipe. It consists of copper-carbonate, iron-carbonate or zinc-carbonate depending upon the type of pipe material which stays over all shiny metal surfaces. This layer helps to protect the pipes against aggressive substances that can cause corrosion.